Product description
Accurate readings, rugged design, easy-to-use: And that’s exactly what you get with the testo 310 Combustion analyzer. You can carry out quick and reliable checks on combustion and heating systems.
The testo 310 entry-level Combustion analyzer for reliable combustion system checks
The testo 310 combustion analyzer has an easy-to-use menu guide, four integrated menus for flue gas, draft, CO ambient air and pressure measurements, a large, easy-to-read display and a backlight for use in all lighting conditions.
But that is not all. The compact combustion analyzer has a wide range of useful features that make it the ideal companion for combustion and heating systems checks. Thanks to the built-in magnet, it can stick to almost any metal object, like a burner for example, leaving both hands free for other tasks. The sensor can be zeroed in as little as 30 seconds and the sensor filter is just as easy to replace. In addition to that, the device has a rugged design which protects it against impact and damage and an easy-to-empty condensate collection tank.
The readings can also be transferred directly to your testo turbo printer (optional) via the combustion analyzer’s infrared interface, allowing you to print out on site.
What's included
testo 310 combustion analyzer, rechargeable battery, calibration certificate for O2, CO,psi and °F measurements, 7 in. conical sensor, silicone tube for pressure measurements, 10x particle filters, case.
| Technical data | |
|---|---|
|
Measuring range |
-20 to +100 °C |
|
Accuracy |
±1 °C |
|
Resolution |
0.1 °C |
|
Reaction time |
< 50 s |
Temperature (ambient temperature)
| Technical data | |
|---|---|
|
Measuring range |
0 to +400 °C |
|
Accuracy |
±1 °C (0 to +100 °C) |
|
Resolution |
0.1 °C |
|
Reaction time |
< 50 s |
Temperature (flue gas)
| Technical data | |
|---|---|
|
Measuring range |
0 to 21 Vol.% |
|
Accuracy |
±0.2 Vol.% |
|
Resolution |
0.1 Vol.% |
|
Reaction time t₉₀ |
30 s |
| Technical data | |
|---|---|
|
Measuring range |
-20 to +20 hPa |
|
Accuracy |
±0.03 hPa (-3.00 to +3.00 hPa) |
|
Resolution |
0.01 hPa |
| Technical data | |
|---|---|
|
Measuring range |
0 to 120 % |
|
Resolution |
0.1 % |
| Technical data | |
|---|---|
|
Measuring range |
0 to 99.9 % |
|
Resolution |
0.1 % |
| Technical data | |
|---|---|
|
Measuring range |
0 to CO₂ max (Display range) |
|
Accuracy |
±0.2 Vol.% |
|
Resolution |
0.1 Vol.% |
|
Reaction time t₉₀ |
< 40 s |
| Technical data | |
|---|---|
|
Measuring range |
-40 to +40 hPa |
|
Accuracy |
±0.5 hPa |
|
Resolution |
0.1 hPa |
| Technical data | |
|---|---|
|
Measuring range |
0 to 4000 ppm |
|
Accuracy |
±20 ppm (0 to 400 ppm) |
|
Resolution |
1 ppm |
|
Reaction time t₉₀ |
60 s |
| Technical data | |
|---|---|
|
Measuring range |
0 to 4000 ppm |
|
Accuracy |
±20 ppm (0 to 400 ppm) |
|
Resolution |
1 ppm |
|
Reaction time |
60 s |
| Technical data | |
|---|---|
|
Warranty |
Instrument: 24 months; Gas sensors: 24 months; Thermocouple 12 months; rechargeable battery: 12 months; Probe: 24 months |
|
Display type |
LCD |
|
Display function |
Backlit 2-line display |
|
Power supply |
Battery: 1500 mAh, mains unit 5V/1A |
|
Storage temperature |
-20 to +50 °C |
|
Weight |
(with probe) Approx. 700 g |
|
Dimensions |
201 x 83 x 44 mm |
|
Operating temperature |
-5 to +45 °C |